IGNITION CONTROL UNIV.ICU PREPURGE/LOCKOU
Add to Quote to request pricing
Details
These kits have a lockout feature to shut off all gas to the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-003 provides 3 tries for ignition, each ignition period is 60 seconds followed by a 5 minute time delay between ignition attempts. After 3 tries if no pilot flame is sensed, unit goes into lockout and must be reset at the thermostat. The 780-003 has a 45 second pre-purge.